Outline
of the SCL-60 Series Inserted-type Ultrasonic Flowmeter |
|
| The
SCL series ultrasonic flowmeter operates on the princile of “speed
difference”off measuring the liquid flow in round pipes.
|
| Thanks
to its use of digitized electronic circuit and the data analysis
and errorcorrection technique,the flowmeter is more adaptable
for use in industrial environment.
|
| The
flowmeter is composed of two parts,i.e the conversion unit and
inserted-type transducer.。
|
| |
| Mounting
of the transducer is made with the special drilling tool of our
company.Through the hole drilled on the pipe on site,the transducer
is inserted about 5 mm inside the pipe,without producing any adyerse
effect on the flow condition,and requiring no process shutdown
during mounting and maintenance |
| The
flowmeter is used for measuring liquid flowrate in round pipes,
with the “velocity different” method as its operating principle,Because
of the use of advanced multi-pulse, digital signal processing
(Dsp) and error-correction techiques,the meter is more ad optable
for use under industrtal envir onment, more convenient in operation
and igher in accuracy.
|
| 
|
Apply Range |
|
|
|
| switch
(Inserted type) Pipe size adaptable:DN80mm~DN4000mm
Overall |
|
| Version Wall |
Size of mounting opening Ac.220V
Power Wall Thickness Adaptable, mm |
| Standard lengt |
< 30 |
| With 40 mm extension |
< 70 |
| With 80 mm extension |
< 110 |
| With 120 mm extension |
< 150 |
| Overall Dimensions of Pipe Section-mounted
Flowrate Transducers(Pipe Size >32 mm) |
|
|
|
|  |
Selection
of conversion unit |
|
| There
are 3 types of conversion units, i.e. non-integral version (wall-mounted),
integral version (mounted onpipe wall) and panel-mounted version
(inlaid on front panel of instrument or that of control cabinet).
A speci alnon-integral version features the use of explosion-proof
transducer to form with the conversion unit mounted in non-hazardous
area an intrinsically safe digital ultrasonic flowmeter.
|
| |
| |
| |
|
Output of conversion unit
|
| mode |
Analog signal
output |
Switching signal
output |
Serial port
output |
Display |
Printer interface |
|
content |
0-10mA
0-20mA
4-20mA |
Electronic switch
output of cumulative flowrate |
RS-485 |
2×16digitalliquid crystal display |
Serial interface
or special print data line |
|
|
| Overall dimensions, mounting dimension (unit: mm)
and weight (unit: kg) |
| Non-integral
type |
| |
| |
|
Weight: 1.4
Mounting dimensions |
|
| Integral
type |
|
| Panel-mounted
type |
|
 |
|
Overall dimensions
Dimensions of mounting opening |
| (
heft: 0.9 )
|
|
|
|
Diagram showing the electrical connection
of terminal of conversion unit |
| |
| Integral
type
Panel-mounted type |
|
 |
|
| 
|
Mounting of Transducer |
|
|
Mounting position
|
| The length of the straight pipe
section should meet the following requirements:The length
of the pipe section on upstream side of transducer should
be no less than 10D (D — pipeID), and that on downstream
side of transducer should be no less than 2D. If the required
conditions are not available on site, a flow-regulating
device should be provided on ups tream side, for reduced
eddies in flow,improved distribution of flow velocity
field, and greater precision and stability of flowmeter.
If a reduced flow velocity may lead to reduction of eddies
and improvement of flow velocity distribution, the length
of he upstream straight pipe section can be shortened
to less than 10D. However, when there exist on upstream
side of transducer, a 90°bend and other flow-resisting
elements, the length of the upstream straight pipe section
is required to be greater than 10D. |
|
Recommended mounting position
|
| (1) The measuring point should be selected on an
upright pipe with either upward or inclined upward flow,
or possibly on a horizontal pipe. Avoid as much as possible,
the use of a transducer on a pipe with downward or inclined
downward flow, as the pipe may not be fully filled with
fluid in this case.
(2) Never mount a transducer at the highest point of a
pipe run because abnormalities in measurement may occur
in this case due to accumulation of air bubbles at this
point of the pipe. |
|
Correct and Incorrect Transducer Mounting
Positions
(Applicable
to Different Types of Transducers)
|
Preferable Position |
Incorrect (No full pipe flow in some cases)
|
Incorrect (Never mount a transducer at the
highest point of a pipe run) |
|
|
|
|
|
|
| (3) On a horizontal pipe, the mounting
position of the transducer should be within±45°from the
horizontal line, for avoiding the contact of ultrasonic
beam with the air bubbles at the top of the pipe. |
|  |
| (4) Mounting space required |
|  |
|
 |
(1)
For the mounting of an inserted
type transducer, the process pipe
should maintain a pressure of
less than 1 MPa (Otherwise, the
pressure should be reduced).
(2) For mounting transducers on
pipes of which the material is
not amenable to welding, special
clamping device and tools are
required (Please specify the pipe
material and pipe OD when ordering). |
|
|
|
Requirements on transducer cable laying |
|
When the transducer cable runs along other cables or is
laid underground, the cable must pull through a metal
conduit with an ID of greater than 25 mm.
|
|
For the overhead cable with a span of 2 adjacent cable
posts exceeding 10 m, reinforcing lines should be used,
for avoiding breakage of cable caused by strong wind blow. |
| 
|
Technical Parameters |
|
| Specification |
Inserted Type |
Pipe section-mounted Type |
Clamped-on Type |
| Transducer |
| Fluid measured |
Water, sewage and other homogeneous fluids
with a content of suspended matters not exceeding
10g/L and a particle size of less than 1 mm |
| Measuring accuracy |
±1.0 |
±1 |
±1.5 |
| Flow velocity adaptable, m/s |
±0.01~±12 |
| Pipe size
adaptable,mm |
DN80-DN4000 |
| Transducer material |
1CR18Ni9Ti (Stainless
steel) |
| Maximum
pressurebearing capacity |
Max.
pressure in pipe at local
places:<2MPa
Immersion depth of
transducer:<3 m |
| Working Environ-ment |
Conversion
unit |
Temperature: -10°C~+45°C, Humidity: 85%
(RH) (For use under otherwise specific
conditions, please specify on ordering). |
|
Transducer |
Normal temperature type: 0~50°C,
High temperature type: 0~150°C. |
|
Cable |
-40℃
~ +70℃ |
|
Output of con-
version unit |
Analog
signal |
Optical-isolated: 4~20mA/0~20mA/0~10mA (Selectable via keyboard), Load capacity:
<600Ω。 |
| Switching
signal |
Cumulative
flow electronic switching output Closing time:
3 ms
Cycle: 6 ms Transmission distance: <500 m. |
| Serial port |
RS-485 Transmission rate: 4800
bit/s Transmission distance: <1200 m。 |
| Printer |
RS-485
is needed for its working
Thermal sensitive mini-printer (Optional) |
| Keyboard |
1×3pushbuttons |
|
Display Mode |
2×16digit
back-lit liquid crystal character display |
| Data display |
Simultaneous display of:
Instantaneous flowrate: -99999.99~+99999.99 M3/h
Cumulative flowrate: -19999999.99~+19999999.99 M3
Key display of cumulative running time |
|
Data storage |
Cumulative
flowrate, cumulative running time and various
set parameters (Data can be saved for 100 year
after power fail) |
| Operating
Power
requirement |
AC220V±15% Power:<10W 50Hz
(DC5~36V, 1A, Please specify on ordering) |
| Protection class |
Transducer |
Conversion
unit |
| IP68 |
Non-integral/Integral type: IP65
Panel-mounted type: IP51 |
| Class
of explosion
resistance of explosion-
proof transducer |
ExibⅡBT6 |
|
length (Cabling distance) |
10m、20m、30m......300m |
|
|
| 
|
Code designation |
|
|
Before selecting the SCL-60x, 61x and 62x digital
ultrasonic flowmeters, please read carefully the preceding
chapters. |
|
Code
|
|
|
|
If it is required for our company to help fill up the
following form, please contact us via e-mail or mail,
and inform us of your liaison mode。 |
| Fluid |
Type |
|
Scale Deposit
Material |
Type |
|
| Temperature, °C |
|
Thickness(mm) |
|
|
Suspended matter, g/l |
|
Pipe Liner |
Material |
|
| Pipe |
Material |
|
Thickness, mm |
|
|
OD, mm |
|
Flowrate |
Thickness,mm |
|
| Wall thickness, mm |
|
Normal, m3/h |
|
|
Length
of straight section, m |
|
Max.,
m3/h
Min., m3/h |
|
| Size of existing flowmeter well
(L×W×H)
of underground pipeline |
|
|
Minimum clearance between surface
pipe and wall |
|
| Transducer cable length |
|
| Remark |
|
|
| Form
Sheet for Digital Ultrasonic Flowmeter Selection(Please
tick off the selected item) |
| Type of transduce |
Inserted
type |
Type
of conver-sion unit |
Integral
type |
|
|
| Pipe section
mounted type |
Non-integral type |
|
|
| Clamped-on type |
Panel-mounted type |
|
|
| SCL-630 portable type |
|
|
|
|
|
|
|