5-6W, Wide Input Range DIP, Single & Dual Output DC/DC Converters
Key Features
‧Efficiency up to 86%
‧1500VDC Isolation
‧MTBF > 1,000,000 Hours
‧2:1 Wide Input Range
‧UL1950 Safety Approval
‧Complies with EN55022 Class A
‧Temperature Performance -40°C to +71°C
‧Industry Standard Pinout
‧UL 94V-0 Package Material
‧IInternal SMD Construction
 
  Selection Guide
Model Number
Input Voltage
Output Voltage
Output Current
Efficiency
Reflected Ripple Current
VDC
VDC
mA
% Typ.
mA Typ.
MIW3011
5
( 4.5 – 7 )
3.3
1200
75
100
MIW3012
5
1000
79
MIW3013
12
500
82
MIW3014
15
400
82
MIW3015
±5
±500
79
MIW3016
±12
±250
82
MIW3017
±15
±200
82
MIW3021
12
( 9 – 18 )
3.3
1200
77
25
MIW3022
5
1000
81
MIW3023
12
500
84
MIW3024
15
400
84
MIW3025
±5
±500
81
MIW3026
±12
±250
84
MIW3027
±15
±200
84
MIW3031
24
( 18 – 36 )
3.3
1200
79
15
MIW3032
5
1000
83
MIW3033
12
500
86
MIW3034
15
400
86
MIW3035
±5
±500
83
MIW3036
±12
±250
86
MIW3037
±15
±200
86
MIW3041
48
( 36 – 75 )
3.3
1200
79
10
MIW3042
5
1000
83
MIW3043
12
500
86
MIW3044
15
400
86
MIW3045
±5
±500
83
MIW3046
±12
±250
86
MIW3047
±15
±200
86
 
 
 

Minmax's MIW3000-Series power modules are low-profile dc-dc converters that operate over input voltage ranges of 4.5-7VDC, 9-18VDC, 18-36VDC and 36-75VDC which provide precisely regulated output voltages of 3.3V, 5V, 12V, 15V, ±5V, ±12V and ±15VDC.

The -40°C to +71°C operating temperature range makes it ideal for data communication equipments, mobile battery driven equipments, distributed power systems, telecommunication equipments, mixed analog/digital subsystems, process/machine control equipments, computer peripheral systems and industrial robot systems.

The modules have a maximum powerrating of 6W and a typical full-loadefficiency of 86%, continuous short circuit, 50mA output ripple, EN55022 Class A conducted noise compliance minimize design-in time, cost and eliminate the need for external filtering

  Mechanical Dimensions
Pin Connections
 
Pin
Singles
Duals
2
-Vin
-Vin
3
-Vin
-Vin
9
No Pin
Common
11
NC
-Vout
14
+Vout
+Vout
16
-Vout
Common
22
+Vin
+Vin
23
+Vin
+Vin
                    NC: No Connection
 
Case Size –
31.8x20.3x10.2mm (1.25x0.80x0.40inch)
Case Material –
Metal with Non-Conductive Baseplate
Weight 16.9g (0.60Oz)
         
Tolerance
 
Millimeters
 
Inches
   
X.X±0.25
 
X.XX±0.01
   
X.XX±0.13
 
X.XXX±0.005
Pin
 
±0.05
 
±0.002
 
 
 
 
 
 
 
 
Absolute Maximum Ratings
Parameter
Min.
Max.
Units
Input Surge Voltage (1000mS)
5VDC Input Models
-0.7
10
VDC
12VDC Input Models
-0.7
25
VDC
24VDC Input Models
-0.7
50
VDC
48VDC Input Models
-0.7
100
VDC
Lead Temperature (1.5mm from case for 10sec.)
---
260
°C
Internal Power Dissipation
---
2500
mW
Exceeding the unit absolute maximum ratings could cause damage. These are not continuous operating ratings.
 
General Characteristics
Parameter
Conditions
Min.
Typ.
Max.
Units
Isolation Voltage
60 Seconds
1500
---
---
VDC
Isolation Resistance
500VDC
1000
---
---
Isolation Capacitance
100kHz, 1V
---
380
550
pF
Switching Frequency
---
300
---
kHz
MTBF
MIL-HDBK-217F @25°C Ground Benign
1
---
---
MHrs
 
Environmental Characteristics
Parameter
Conditions
Min.
Max.
Units
Operating Temperature
Ambient
-40
+71
°C
Operating Temperature
Case
-40
+90
°C
Storage Temperature
-40
+125
°C
Humidity
---
95
%
Cooling
Free-Air Convection
Conducted EMI
EN55022 Class A
 
Output Characteristics
Parameter
Conditions
Min.
Typ.
Max.
Units
Line Regulation
Vin = Min. to Max.
---
±0.1
±0.3
%
Load Regulation
Io = 20% to 100%
---
±0.3
±1.0
%
Ripple & Noise
20MHz BW
---
50
75
mV P-P
Short Circuit
Continuous
 
Maximum Capacitive Load
Models by Output Voltage
(Each Output on Duals)
Singles
Duals
Units
6800
1000
uF
     
Derating Curve
 
Notes :
1. Specifications typical at Ta=+25°C, resistive load, nominal input voltage, rated output current unless otherwise noted.
2. Transient recovery time is measured to within 1% error band for a load step change of 75% to 100%.
3. These power converters require a minimum output load to maintain specified regulation.
4. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed.
5. All DC/DC converters should be externally fused at the front end for protection.
6. Other input and output voltage may be available, please contact factory.