MINMAX 模块电源

2-3W, Wide Input Range DIP, Single & Dual Output DC/DC Converters
Key Features
‧Efficiency up to 84%
‧1500VDC Isolation
‧MTBF > 1,000,000 Hours
‧2:1 Wide Input Range
‧UL1950 Safety Approval
‧Low Cost
‧Temperature Performance -40°C to +71°C
‧Industry Standard Pinout
‧UL 94V-0 Package Material
‧Internal SMD Construction
 
  Selection Guide
Model Number
Input Voltage
Output Voltage
Output Current
Efficiency
Reflected Ripple Current
VDC
VDC
mA
% Typ.
mA Typ.
MIW1011
5
( 4.5 – 9 )
3.3
600
70
100
MIW1012
5
500
73
MIW1013
12
250
77
MIW1014
15
200
77
MIW1015
±5
±250
72
MIW1016
±12
±125
75
MIW1017
±15
±100
75
MIW1021
12
( 9 – 18 )
3.3
600
74
30
MIW1022
5
500
78
MIW1023
12
250
82
MIW1024
15
200
82
MIW1025
±5
±250
77
MIW1026
±12
±125
80
MIW1027
±15
±100
80
MIW1031
24
( 18 – 36 )
3.3
600
76
15
MIW1032
5
500
79
MIW1033
12
250
84
MIW1034
15
200
84
MIW1035
±5
±250
79
MIW1036
±12
±125
82
MIW1037
±15
±100
82
MIW1041
48
( 36 – 72 )
3.3
600
76
10
MIW1042
5
500
79
MIW1043
12
250
84
MIW1044
15
200
84
MIW1045
±5
±250
80
MIW1046
±12
±125
84
MIW1047
±15
±100
84
     
 

Minmax's MIW1000-Series power modules are low-profile dc-dc converters that operate over input voltage ranges of 4.5-9VDC, 9-18VDC, 18-36VDC and 36-72VDC which provide precisely regulated output voltages of 3.3V, 5V,12V, 15V, ±5V, ±12V and ±15VDC.

The -40°C to +71°C operating temperature range makes it ideal for data communication equipments, mobile battery driven equipments, distributed power systems, telecommunication equipments, mixed analog/digital subsystems, process/machine control equipments, computer peripheral systems and industrial robot systems.

The modules have a maximum power rating of 3W and a typical full-load efficiency of 84%, continuous short circuit, 45mV output ripple, built-in filtering for both input and output minimize the need for external filtering.

  Mechanical Dimensions
Pin Connections
 
Pin
Singles
Duals
2
-Vin
-Vin
3
-Vin
-Vin
9
No Pin
Common
11
NC
-Vout
14
+Vout
+Vout
16
-Vout
Common
22
+Vin
+Vin
23
+Vin
+Vin
                     NC: No Connection
 
Case Size –
31.8x20.3x10.2mm (1.25x0.80x0.40inch)
Case Material –
Non-Conductive Black Plastic
Weight – 12.0g (0.42Oz)
         
Tolerance
 
Millimeters
 
Inches
   
X.X±0.25
 
X.XX±0.01
   
X.XX±0.13
 
X.XXX±0.005
Pin
 
±0.05
 
±0.002
 
 
 
 
 
     
 
Absolute Maximum Ratings
Parameter
Min.
Max.
Units
Input Surge Voltage (1000mS)
5VDC Input Models
-0.7
11
VDC
12VDC Input Models
-0.7
25
VDC
24VDC Input Models
-0.7
50
VDC
48VDC Input Models
-0.7
100
VDC
Lead Temperature
(1.5mm from case for 10sec.)
---
260
°C
Internal Power Dissipation
---
2500
mW
Exceeding the unit absolute maximum ratings could cause damage. These are not continuous operating ratings.
 
General Characteristics
Parameter
Conditions
Min.
Typ.
Max.
Units
Isolation Voltage
60 Seconds
1500
---
---
VDC
Isolation Resistance
500VDC
1000
---
---
Isolation Capacitance
100kHz, 1V
---
65
100
pF
Switching Frequency  
---
300
---
kHz
MTBF
MIL-HDBK-217F @25°C Ground Benign
1
---
---
MHrs
 
Environmental Characteristics
Parameter
Conditions
Min.
Max.
Units
Operating Temperature
Ambient
-40
+71
°C
Operating Temperature
Case
-40
+90
°C
Storage Temperature
-40
+125
°C
Humidity
---
95
%
Cooling
Free-Air Convection
 
Output Characteristics
Parameter
Conditions
Min.
Typ.
Max.
Units
Line Regulation
Vin = Min. to Max.
---
±0.2
±0.5
%
Load Regulation
Io = 10% to 100%
---
±0.2
±0.5
%
Ripple & Noise
20MHz BW
---
45
60
mV P-P
Short Circuit
Continuous
 
Maximum Capacitive Load
Models by Outpu tVoltage
(Each Output on Duals)
Singles
Duals
Units
4000
1000
uF
     
Derating Curve
 
Notes :
1. Specifications typical at Ta=+25°C, resistive load, nominal input voltage, rated output current unless otherwise noted.
2. Transient recovery time is measured to within 1% error band for a load step change of 50% to 100%.
3. These power converters require a minimum output load to maintain specified regulation.
4. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed.
5. All DC/DC converters should be externally fused at the front end for protection.
6. Other input and output voltage may be available, please contact factory.
7. All specifications subject to change without notice.
 